| Type of Fuel | Propane Gas |
| Safety Engineering | N/A Heat Exchanger: Film Wrap Overheat Limiter Flame Failure Safety Monitor: Flame Rod Type Anti-boil protection |
| Vent Length Maximum | N/A |
| Rated Gas Input (BTU's/Hr.) | 19,000 - 199,900 (modulating) |
| Dimensions (inches) | 14-7/8 (W) x 25-3/8 (H) x 11-1/8 (D) |
| Net Weight (lbs.) | 55 |
| Working Water Pressure | 14 psi (minimum); 150 psi (maximum) |
| Minimum Flow for Ignition | 0.66 GPM |
| Gas Connection | 3/4" NPT Male |
| Thermal Efficiency | 0.82 |
| Energy Factor (DOE) | 0.82 |
| Electrical Requirement | 120 VAC/60 Hz,Less than 2 Amps |
| Freeze Protection | Minus 30° F (including wind chill factor) |
| Controller/Diagnostic Display | Main Unit Remote Control - UMC-117 (included) |
Multi-Unit System Controller (sold separately) | 2 to 6 units Controller System: MIC-180 (includes installation box) 7 to 20-unit system: MIC-180 + MICS-180 (contact us for more information) |
| • Factory-set maximum temperature is 120° F |
| • For installations above 3,280 feet,the connector to the PC board must be replaced. Consult factory or your supplier for details. |
| This heater is also available in different Models |
Residential Paloma PH-28R IFSN - Indoor - Natural Gas Tankless Water Heater Paloma PH-28R IFSP - Indoor - Propane Tankless Water Heater Paloma PH-28R OFN - Outdoor - Natural Gas Tankless Water Heater Paloma PH-28R OFP - Outdoor - Propane Tankless Water Heater Paloma PH-28R DVSN - Direct Vent - Natural Gas Tankless Water Heater Paloma PH-28R DVSP- Direct Vent - Propane Tankless Water Heater | Commercial Paloma PH-28C IFSN - Indoor - Propane Tankless Water Heater Paloma PH-28C IFSP - Indoor - Propane Tankless Water Heater Paloma PH-28C OFN - Outdoor - Natural Gas Tankless Water Heater Paloma PH-28C DVSN - Direct Vent - Natural Gas Tankless Water Heater Paloma PH-28C DVSP- Direct Vent - Propane Tankless Water Heater |
In the commercial hot-water world,the 28c Series may be the only tankless solution you will ever need to know.
With the 28c as your platform,you can solve the needs of a small restaurant kitchen,a school shower facility,or a large National Guard training base. The 28c can be used standalone,or it can be configured into multi-unit systems of 2 to 20 units controlled with Paloma's Manifold Electronic Controller.
Why use Paloma's Expandable Tankless Water Heater instead of conventional hot-water solutions?
- Standard components - You can standardize your design of hot water systems from 200,000 to 4.0 million BTU's on a single,common component - the Paloma 28c.
- Scalability - Systems can be designed to be expanded over time to accommodate increasing hot-water requirements.
- Installation ease - Each unit you carry in weighs just 55 pounds,and you have leeway in designing the installation around space limitations of your mechanical room.
- Built-in redundancy - Even if one unit requires servicing,other units in your system will continue to provide hot water. It is not necessary to shut down the entire system to service a single unit.
- Servicing flexibility - You can,in fact,swap units out for offsite servicing if you wish.
- Smart energy use - Just like a tankless system for home use,commercial applications can also leverage the Paloma's �on demand� energy-wise performance.
Multi-Unit Systems
A large system of 28c Paloma's can be electronically controlled with the MIC-180 Manifold Controller. For systems of 7 to 20 units,the MIC-180 Controller needs an extended communication board,the MICS-180,which can be fit inside the MIC-180 installation box.
Single-Unit Controller
The UMC-117 Main Controller is used to set temperatures,display error codes and access maintenance information on a single-unit installation. In multi-unit systems,one Main Controller is used as the temperature controller and error display for the entire system. Others continue to be used to display diagnostic information on specific units.
Features:
- Endless hot water on demand
- Energy efficiency - heats water only when it is needed
- Compact,and takes no floor space (wall-hung installation)
- Unmatched Safety Engineering
- Proprietary ICAD Safety System (on indoor model)
- Proprietary Film Wrap Overheat Limiter (on heat exchanger)
- Flame failure and anti-boil protection
- Freeze protection to minus 30 degrees F
- Built-in diagnostics and usage record
- Includes Digital Controller to set temperature and display diagnostics
- 180-degrees F maximum temperature setting
- Minimum flow for ignition: 0.66 GPM
- Power Return: AUTO-ON at last setting after power interruption
- Low NOx emissions meet SCAQMD Rule 1146 requirements
- Can be used in circulation systems up to 140 degrees F
Multi-Unit System Features:
- 1- to 20-unit systems with 199,900 to 3.99 million BTU's/hr. inputs
- MIC-180 Manifold Controller quickly and tightly calibrates firing,temperature and volume output of each unit in system
- Control logic distributes heating load to maximize system life
- Can be delivered and installed in tight locations
- Built-in system back-up
- Units can be serviced without shutting down the entire system
Commercial Warranty
- 3-Year Limited Warranty on Heat Exchanger
- 1-Year Limited Warranty on Parts